Building academy2026-11-15T19:17:48+01:00

Choose a product group

Metal roofing

Blachy trapezowe — ilustracja kategorii

Sandwich panels

Płyty warstwowe — ilustracja kategorii

PIR insulation boards

Płyta izolacyjna PIR z cienką folią — ilustracja kategorii

XPS

Płyty XPS — ilustracja kategorii

Accessories

Wkręty i łączniki — ilustracja kategorii

Fencing

Sztachety metalowe — ilustracja kategorii

Building academy

The Izoprofil.org building academy explains decisions made during construction and refurbishment. The articles start with the materials themselves, including sandwich panels, PIR insulation boards and profiled sheet metal. Learn the terms used in product descriptions and how several properties affect a complete assembly. Topics include thermal insulation, joints, moisture protection, roof coverings and purchasing. Each article includes a summary and contents to help you find the relevant detail. Use the guides alongside the drawings and product documentation for your own project.

BauderPIR FA-TE: identifying the edge profile and correct variant

A local unevenness in the surface of a terrace with BauderPIR FA-TE requires establishing whether its source is the support and the pressure of the pedestals, the layers above the insulation, or the material itself. Identification begins with naming the observed symptom and the conditions in which it arose, not with an assessment of the quality of the PIR. With this product, the key place for inspection is the threshold of the terrace door and the nearby drain, where the distance between the substrate and the permissible surface level is checked. The reference point is the terrace cross-section at the door with marked levels, allowing the symptom to be related to the intended layer build-up.

How roof panel thickness affects indoor conditions

The roof panel thickness must be matched to the required thermal insulation and the way the interior is used. The number of millimetres alone does not describe the core, the tightness of the joints or the load-bearing capacity. It is worth comparing specific U-values and then checking the details and the construction. Only such a set of data allows you to assess whether the selected variant will meet the objective. First, determine the temperature and the heating time. A pavilion opened for a few hours a day has a different operating rhythm from a continuously heated unit. Humidity and air exchange are also important. Cooking, wet processes or frequently bringing in damp items can increase the amount of vapour in the interior. This cannot be described by the floor area alone.

Damp at a metal roof ridge: leaking ridge caps or a ventilation problem?

A stain below the ridge does not yet indicate the point where water entered the roof. Precipitation may have penetrated through a poorly executed joint. Moisture can also form beneath the covering as condensation. Ridge tiles must be assessed together with the roof slope layers. Only then is it clear whether the flashing needs repair or the ventilation detail needs changing. Simply adding sealant is often a seemingly simple solution. However, it can block the airflow path. Note whether the damp patches occur after rain, during a thaw, or also on dry days. Information on wind direction is helpful. A leak visible only during rainfall from one side suggests a different point to check than drops appearing in the morning under a large part of the roof slope. These are pointers for inspection, not a ready diagnosis.

Double-sided metal fence pickets: colour on both sides or two rows?

The word "double-sided" appears very often in offers for fence pickets. It may describe the finish of the sheet metal or the way the fence is built. These meanings are easily confused. The result can be costly: a different number of elements, an unexpected colour on the reverse, or less privacy screening. It is worth separating both decisions before measuring and quoting. Metal fence pickets can then be ordered without guesswork. In the first meaning, it is about the coating. The picket has a decorative finish on both the front and the back. When viewing the fence from the property, there is therefore no technical reverse with a different appearance. However, this does not change the number of elements needed to make a single row.

What belongs beneath the roof covering? Support, drainage and ventilation

A roof substrate is not a single element but a set of layers with different jobs. Battens and boarding carry the loads, while a membrane or other underlay directs water away; counter-battens create a ventilation gap. The choice depends on the roof and covering type – no universal arrangement suits every metal sheet. Before comparing offers, establish what each item includes, as the term may refer to the batten grid, full boarding or just the membrane. Leave the layout decision to the designer.

When should you choose a PIR board 120 × 60 cm and when a larger format?

The board format affects the number of joints, the way it is handled and the amount of waste. Smaller elements can be more convenient in a tight interior. Larger ones allow a large area to be covered with fewer pieces. However, a distinction must be made between the nominal dimension and the effective coverage. A rebate on the edge can reduce the area that the board actually covers. One family of foil-faced PIR boards includes formats 600 × 1200 and 1200 × 2400 mm. Nominally these correspond to 0.72 and 2.88 m². The large board therefore has four times the rectangular area. This does not mean that every PIR is available in both sizes and all thicknesses.