Why does standing seam shed water and what can weaken its watertightness?

In a standing seam roof, the joint is raised above the flat part of the covering. Water runs off primarily between the longitudinal lines. This is a favourable geometry, but it does not provide resistance to every error. The roof still needs the correct pitch, substrate and flashings. The areas requiring the most attention are those where the straightforward direction of run-off is interrupted. The folded edges of the sheet form the standing seam. The main surface of the roof slope sits lower than its upper part. With a correct layout, water does not stand over the full height of the joint. This does not mean, however, that it may pond freely between the strips. The roof must retain the designed direction and continuity of drainage.

2026-11-14T10:54:24+01:00

When does a sandwich panel roof suit the extension of an old building?

Roof panels can form part of the extension of an existing building. Their use must, however, be matched to the structure and to the new function of the interior. The junction between the old and new parts is often the most difficult. Differential movements, drainage and loads at the higher wall all come into play. The panel should be selected after these conditions have been established. Information is needed on the structure, the condition of the materials and earlier alterations. Corrosion of steel, dampness in timber or damage to masonry can limit the possibility of using existing elements. The assessment is carried out on site. An old drawing alone does not confirm the current condition.

2026-11-14T13:15:12+01:00

Roofing a heated or unheated garage

The choice of garage roof is determined primarily by the interior temperature and how the space is used. Check whether the garage will serve only for parking or also as a workshop all year round, because a car brings in water and moisture even without heating. For a heated interior, allow for insulation and tight joints; for an unheated one, suitable trapezoidal sheet may suffice. Also check ventilation, drainage and any planned roof equipment so that the solution matches the actual conditions.

2026-11-14T20:37:37+01:00

Utherm Roof LE: why a good lambda value is not enough for a roof

A cooler zone at the parapet does not yet tell you whether the problem concerns Utherm Roof LE. The termination of the insulation layer or air flow through a leak may be significant. When assessing a roof, it is worth separating the properties of the board from the condition of the details executed on site. Utherm Roof LE is a PIR board intended for flat roofs and roofs with a low pitch. The core is covered on both sides by a multi-layer, gas-tight laminate. The terms “polyurethane boards” and “polyurethane foam” are broader than the precise designation of the PIR product. When assessing the performance of the building envelope, it is worth checking the limited insulation height at the roof parapet with Utherm Roof LE. Before assessing the solution, the thickness of Roof LE, the taper and the remaining roof layers must be added together.

2026-11-16T03:17:42+01:00

Choosing the material and thickness for roof insulation

Decide where the insulation will enclose the heated space and what thermal performance the complete roof needs to achieve. A rafter slope, a top-floor ceiling and a flat roof require different build-ups. In an existing building, check the timber for damp and allow space for services and finishes before comparing insulation thicknesses. An unused loft can often remain outside the heated space if the insulation runs across the ceiling below it. In that case there may be no need to insulate the slopes as well.

2026-11-15T04:20:52+01:00

Cold-formed and hot-rolled channels: why matching their height is not enough

When buying steel, it is easy to reduce a description to two words and one number. “Channel 200” sounds unambiguous, but it does not define the full product. It could refer to a cold-formed profile or a rolled product. The differences are not only in weight. The geometry of the walls, the method of connection and the working conditions also differ. A conscious choice begins with the question of what function the element is to perform and according to which data it was selected. The web height helps describe the cross-section, but it does not say everything about the quantity and distribution of material. The flange widths, wall thickness and corner radii are important. In C profiles, there are also stiffening bends at the ends of the flanges. Two channels of the same height can therefore have clearly different properties. They must not be equated solely on the basis of external dimensions.

2026-11-15T19:30:39+01:00

What to check before specifying load-bearing trapezoidal steel sheet

The choice of structural trapezoidal sheet depends on the complete load-bearing system, not on profile height alone. The sheet transfers loads between supports and forms the substrate for subsequent roof layers. Steel thickness, span and support arrangement must be checked, along with loads including snow, wind and any installations. Manufacturer tables serve calculations for a specific partition, so a T18 or T35 designation is not enough. Wind pressure and suction must also be distinguished, and connections to the support verified. The designer decides on the sheet as a load-bearing element of a defined system.

2026-11-15T00:23:22+01:00

Why is termPIR ETX installed with the printed side facing the wall?

termPIR ETX is a PIR board faced on both sides with a gas-permeable glass fleece, intended for two-layer walls in the ETICS system. According to the manufacturer's instruction, the printed side is laid facing the wall. The similar appearance of both surfaces is therefore not enough to determine the board's orientation. When assessing an existing façade, the product marking, its position and its interaction with the adhesive and the other system layers must be checked. The reveal requires separate attention: the insulation thickness in the wall field does not prove that the insulation is continuous at the frame. The guide explains the choice of installation direction, the locations of potential gaps and the data needed before repairing the window junction.

2026-11-16T03:16:15+01:00

What length should I order for wall and roof sandwich panels?

The panel length is matched to the building and the installation method. A longer element can reduce the number of joints but make transport and lifting more difficult. A wall is planned differently from a roof. The production range is only the first piece of information. It does not state the distance over which the panel can carry loads without additional supports. The range depends on the core, thickness, colour and specific family. Selected wall and roof PIR panels are offered up to 16.5 m, with restrictions for individual variants. Other types have shorter ranges. There is no single maximum length for all sandwich panels.

2026-11-14T13:14:40+01:00

Does CS(10) show how much load a PIR-insulated floor can bear?

The number given for the compression of the board is not the finished load-bearing capacity of the floor. Assessing it requires the duration of loading, the pressure area and the construction of the substrate. PIR boards can perform well beneath a floor finish when the selection covers these relationships and the actual pattern of use. PIR boards are useful in a floor where the available height is limited. Low thermal conductivity allows an effective insulation layer to fit beneath the screed. A cold floor does not always indicate insulation that is too thin. The floor edges, the type of heating and the finishing layer may all be significant. The temperature of the finish depends on the conditions on both sides of the floor and on how the heating operates. The sensation of cold may differ between floor coverings even at a similar temperature.

2026-11-16T03:16:01+01:00