About PiVi

This author has not yet filled in any details.
So far PiVi has created 1504 blog entries.

How design, prefabrication and energy planning fit together in modern construction

In Poland, modern construction relies on precise design, prefabrication and better energy control rather than on a product's name alone. Readers should check whether the claimed benefit follows from current property documents and suits the building's function. A digital model and drawings help establish hole positions, element lengths and connection methods in advance, especially for cut-to-size sheets and sandwich panels. An error discovered after production may mean rework or unnecessary waste. Consistent information passed to all construction participants is as important as the design itself.

By |2026-11-14T17:10:46+01:002022-01-27|Building academy|Comments Off on How design, prefabrication and energy planning fit together in modern construction

When does fleece under trapezoidal steel sheet reduce condensation dripping?

Fleece on the underside of the sheet metal can reduce dripping water from condensation. It acts as a temporary buffer. It absorbs some moisture and then must release it. Without conditions for drying, its capacity comes to an end. Therefore, the suitability of sheet metal with fleece is determined by the entire roof assembly and ventilation, not by the presence of the soft layer under the sheet alone. Moist air can come into contact with a surface colder than the dew point temperature. Then vapour condenses on the underside of the covering. The phenomenon can also occur without precipitation. Not every trace of water under the roof therefore means a hole or a defective lap.

By |2026-11-14T13:14:22+01:002022-01-18|Building academy|Comments Off on When does fleece under trapezoidal steel sheet reduce condensation dripping?

Cold spots in a PIR-insulated roof: checking insulation continuity

A well-insulated roof field can adjoin a weak detail at the eaves or at a window. PIR boards do not rule out such a situation. The diagnosis should distinguish a thermal bridge from air leakage and moisture. Only then can the necessary repair be selected. PIR boards laid above the rafters form a layer that also covers the wooden structural elements. This can reduce their contribution to the flow of heat through the roof. Recurring cooler strips may show the run of the structure. Assessing them requires knowing whether the PIR lies above the rafters, between them or below them. It is worth comparing the run of the cooler strips with the rafter spacing. If the insulation is located between them, the timber takes part in a different path of heat flow.

By |2026-11-16T03:15:58+01:002021-12-29|Building academy|Comments Off on Cold spots in a PIR-insulated roof: checking insulation continuity

Does the Powerroof tongue-and-groove joint eliminate every thermal bridge?

The tongue-and-groove joint on all four edges of Powerroof brings adjacent PIR boards together in a way that facilitates continuous contact, but it does not eliminate all thermal bridges in a pitched roof. The edge profile alone does not determine the behaviour at the eaves, the ridge or at the points where fasteners penetrate the above-rafter insulation layer. Recticel Powerroof is a PIR board with aluminium facing, intended for above-rafter thermal insulation; its position above the rafters must be read from the course of the layer and the method of fixing the covering, not from the appearance of the joined boards alone. Continuous insulation does not, after all, take over the function of the elements that transfer forces from the covering to the timber structure.

By |2026-11-16T03:25:36+01:002021-12-11|Building academy|Comments Off on Does the Powerroof tongue-and-groove joint eliminate every thermal bridge?

Roof renovation on a tight budget: where cutting costs is a mistake

A limited budget requires setting priorities, not randomly crossing items off the cost estimate. The cheapest quote may cover fewer works than are needed for a durable repair. Corrugated fibre cement sheets should be priced together with the structure, fixings and finishes. Asbestos-free fibre cement can be part of a sensible renovation if the scope matches the condition of the building. It is worth saving on unnecessary works and good organisation while retaining the required roof functions. A leak may come from flashings, fixings, a damaged sheet or a blocked gutter. Moisture under the roof slope may also result from condensation. Each cause requires a different action. Spending money on material before an inspection risks repairing the wrong place.

By |2026-11-15T19:36:34+01:002021-12-04|Building academy|Comments Off on Roof renovation on a tight budget: where cutting costs is a mistake

Fibre cement roofing on an extension: connecting to the existing house

The roof of an extension often has a simple shape, but the junction with the existing building is difficult. Water runs off close to the wall, and the new structure may behave differently from the old one. Fibre cement sheets must be matched to the whole system, not just to the appearance of the house. Asbestos-free fibre cement can be considered as a covering if the pitch, the support and the details meet the requirements of the given system. The place where the new roof slope ends usually requires the most attention. The level of the windows, the eaves of the old house and the height of the new wall limit the shape of the roof. The actual pitch, the length of the run-off and the space for the layers must be checked. It is not enough to choose the thinnest covering if there is insufficient height for the thermal insulation or for the required detail.

By |2026-11-16T03:14:20+01:002021-11-09|Building academy|Comments Off on Fibre cement roofing on an extension: connecting to the existing house

Is the old roof structure suitable for new corrugated roofing?

Replacing the sheets does not mean that the entire roof structure always has to be replaced. Nor does it justify leaving it without inspection. Corrugated fibre cement sheets require a structure suited to the weight, loads and method of fixing. Asbestos-free fibre cement can be considered for a renovated building only after assessing the existing roof. The key question is whether the old elements and connections will safely perform their function in the new arrangement. It is worth checking whether the roof was raised, extended or repaired after damage. Past alterations may not be visible on the original design. Periods of leakage, dampness and major internal alterations should be noted. Removing a wall or adding equipment may affect the structure.

By |2026-11-15T19:36:16+01:002021-11-09|Building academy|Comments Off on Is the old roof structure suitable for new corrugated roofing?

Thermano Roof and point loads: avoiding overestimates of board strength

The rigidity of Thermano Roof does not by itself determine the permissible loads: what matters is where the force is applied and how long it acts. The board is a rigid PIR product with a gas-tight multilayer aluminium facing on both sides; the manufacturer specifies it for, among other things, flat roofs and above-rafter insulation. In a pitched roof it lies above the rafters, so the assessment concerns its connection to the terminations at the eaves and at openings. The bearing surface, the duration of the load and the behaviour of the other roof layers determine whether the hardness of the board has been overestimated.

By |2026-11-16T03:16:29+01:002021-10-30|Building academy|Comments Off on Thermano Roof and point loads: avoiding overestimates of board strength

Do closed cells mean the same thing in PIR and XPS?

The PIR keyword instead of XPS sounds simple, but it hides several different questions. Is it about reduced thickness, performance under load, or contact with water? Each answer requires different data. PIR boards should be compared with a specific product and in a defined section, without creating a single ranking for all applications. In many comparisons, PIR boards with aluminium foil facing have a lower lambda than selected XPS boards. As a result, the required thermal resistance can be achieved with a smaller thickness. However, the value must be checked for both specific products. With XPS, as with some PIR variants, the thickness range can affect the declaration.

By |2026-11-16T03:15:47+01:002021-09-08|Building academy|Comments Off on Do closed cells mean the same thing in PIR and XPS?

EFYOS BLUE SMART A: what a 2.08% slope means in practice

The slope given for EFYOS BLUE SMART A describes the geometry of the element itself, not of the finished roof assembly. That is why in an existing building standing water on the roof must first be linked to a specific location: the lowest section of thermal insulation next to the outlet. Only measuring the level of the outlet and the heights of the ends of the slope fields allows the symptom to be related to the laying of the tapered boards. The mere presence of tapered insulation boards does not prove that the assembly has retained the designed geometry — incorrect orientation of a taper, a difference in the levels of the substrate or a problem at the drainage outlet are all possible. The diagnosis begins with identifying the observed problem and the conditions in which it arose.

By |2026-11-16T03:16:58+01:002021-08-04|Building academy|Comments Off on EFYOS BLUE SMART A: what a 2.08% slope means in practice
Back to top