An autumn roof inspection before the first frost

An autumn roof inspection should be planned before frost makes safe work and the use of repair materials difficult. The owner should check the covering, flashings, gutters and signs of damp in the attic rather than wait for the first leak. The decisive factor is the weather window: an inspection carried out in advance leaves time for repair and a follow-up check. Near trees, leaves may need removing again after the main fall, so a single September check does not guarantee clear gutters in late November.

2026-11-15T04:20:48+01:00

Five reasons to consider sheet metal façade cladding

A metal sheet façade can transform a building's appearance and provide durable cladding, provided the T18 or T35 trapezoidal sheet is correctly selected and fixed. It is worth checking whether the chosen profile suits the project and the product's intended use, and assessing the condition of the substrate and the load-bearing capacity of the substructure. Planning sheet divisions and the arrangement of windows and corners is also key, as it facilitates installation and orders the façade's rhythm. Design decisions should be left to the designer.

2026-11-14T20:34:45+01:00

SOPREMA EFIGREEN ITE: the function of the facing and board joint

A symptom at the window in a wall insulated with the ITE system requires establishing whether it concerns the board itself or the entire assembly with the façade facing. In the case of EFIGREEN ITE, the inspection must be based on the external window reveal and the adjacent façade bracket, because that is where the layers intersect. The mere presence of a tongue and groove does not eliminate thermal bridges from elements penetrating the insulation. The diagnosis should therefore indicate which part of the joint was actually examined, what width the reveal has and how the fixings were routed through the thermal insulation layer. Without this, it is impossible to separate the properties of the board from the behaviour of the entire assembly.

2026-11-16T03:25:47+01:00

How to set out and fit modular tile-effect sheets on a sloping roof

The key to a successful installation of modular metal roofing tiles is to establish the batten spacing precisely from the instructions for the specific model, not from dimensions carried over from another profile. Before laying the sheets, check the geometry and condition of the substrate and plan the eaves details and water drainage. Also confirm that the covering suits the roof pitch. Differences in the pressing can prevent the module from being supported correctly, so verify the dimensions and fixing sequence for the chosen product before starting permanent fixing.

2026-11-15T04:21:19+01:00

T8 on the façade: how to use a low profile without the waviness effect?

T8 has a delicate pattern and may suit soffits, gates or a small wall. However, a low profile does not hide errors in the substructure. On large areas, unevenness and movement of the sheet metal are easier to notice. It is worth starting with the scale of the surface and only then moving on to colour. Below we explain how to read the dimensions and where the limits of this material lie. The T8 designation usually refers to a low façade profile. In one variant, the height is 8 mm, the overall width is 1220 mm and the cover width is 1156 mm. Sheets are available in thicknesses of 0.5 or 0.7 mm. The recommended maximum length is 6 and 7 m respectively. This is an example product, not a common set of dimensions for the whole group.

2026-11-14T10:54:22+01:00

IKO enertherm KR ALU: assessing insulation beneath underfloor heating

Assessing the insulation under heating begins with establishing whether the uneven floor temperature results from the IKO enertherm KR ALU layer or from the pipe layout, the controls or the finish. The board alone does not determine the heat distribution. The proper reference point is the floor cross-section at the threshold between rooms and at the service penetration, with the layer thicknesses shown separately and the height from the substrate to the finished floor. Drawings and photographs taken before the screed was laid allow the actual pipe run to be reconstructed, which the print on the board does not document.

2026-11-16T03:17:30+01:00

What must be maintained for a PIR roof to meet fire requirements during use?

The fire properties of the roof result from a specific arrangement of panels and joints. After acceptance, later openings, repairs and changes to equipment also matter. In a small building it is easy to treat these as minor works. However, every change should preserve the conditions on which the selection of the entire assembly was based. PIR describes the core material, but does not give the full classification of the panel. The facings, thickness and joint construction are important. Identification of the exact variant is needed. Data cannot be transferred from a similar product solely on the basis of the foam name.

2026-11-14T13:15:29+01:00

Choosing a gutter system for sheet metal roofing

In Poland, gutters for a metal-sheet roof are selected primarily according to the roof geometry and the arrangement of outlets, not merely the type of sheet. Readers should check which part of the roof drains to a given gutter section, especially at valleys and with a complex building form. They should also examine the number and position of downpipes and the material compatibility of the system. Leave the choice of cross-section and shape to the designer, based on the specific system's data.

2026-11-14T17:11:37+01:00

Modules or long sheets of tile-effect metal roofing: which suits your roof slope better?

A small module is easier to carry and to fit to a complex roof slope. A long sheet can efficiently cover a simple area. Neither solution wins on every building, however. You need to compare the cutting layout, delivery conditions and the requirements of the chosen profile. It also matters how a damaged section will be replaced later. A module has a fixed length and coverage width. Repeated elements form successive rows. Made-to-measure sheets are ordered in selected lengths, within the limits of the given technology. In both solutions, side joints remain. Long strips can reduce the number of transverse laps on a simple roof slope.

2026-11-14T10:54:09+01:00

Does Eurofloor foil direct all the heat upwards? How it works

The question about the foil on Eurofloor is whether its surface alone directs heat towards the room. The board has a rigid PIR foam core and a multi-layer, gas-tight foil with a printed grid on both sides; the manufacturer intends it for thermal insulation of floors, including those with underfloor heating. Heat is retained primarily by the thermal resistance of the core, not by any reflection of radiation beneath the screed. Eurofloor must therefore be identified in the floor cross-section as a layer beneath the designed heating installation, and not as a mere screen on the surface.

2026-11-16T03:25:29+01:00
Back to top