Polystyrene and thermal insulation
How should a heated basement wall be insulated with EPS?
At a glance
A heated basement is part of the heated section of the building. Its walls must therefore be protected against heat losses and against water. The polystyrene is selected for use in contact with the ground, not only for the expected thickness. The most difficult places are the junction with the floor, the plinth and the basement windows. In an existing house, the extent to which the walls are exposed requires a prior assessment of the structure. If a heated study or recreation room is to be created in the basement, the insulation must not end at ground-floor level. The thermal boundary then includes the basement walls and its floor. The stairs, external doors, windows and adjacent unheated rooms must also be checked. Insulating just one section of the wall will leave other paths for heat loss.

Where does the boundary of the heated part run?
The planned room temperature should be determined before selecting the layers. A continuously heated basement and a space heated only occasionally have different patterns of use. A change of function also affects ventilation and humidity. Adding a radiator is not enough if the existing building components and water protection measures have not been prepared for such conditions.
Why does it usually start from the outside?
External insulation limits cooling of the wall and allows the basement insulation to be connected with the façade. In a new building it can be installed before the walls are backfilled. In a retrofit, access is more difficult. Ground installations, window wells, steps and the feasibility of safely excavating next to the existing foundation must be taken into account.
The entire old house must not be excavated without an assessment of the structure and of how the work is to be carried out. Exposing the walls can change the conditions of their support or drainage. The designer determines the scope of work and the sequence of sections. Where access from outside is impossible, internal insulation requires a separate moisture analysis and a solution for the junctions with the floors.
Which board will be suitable?
In the documentation, look for suitability for walls in contact with the ground. Low water absorption is important, but it does not replace waterproofing. The WL(T), or possibly WD(V), parameters should be assessed in relation to the water present at the building. The backfill pressures and the long-term deformation of the board under load are also important.
Lambda λD is used to compare heat conduction. For example, a 0.15 m layer with λ = 0.036 W/(m·K) has a calculated thermal resistance of about 4.17 m²K/W. This is the resistance of the layer itself, not the result for the basement wall. In the calculation of the building component, the masonry, the ground conditions and the junctions are taken into account. Density or colour do not replace these data.
How should the plinth and basement windows be detailed?
The thermal insulation should continue from the below-ground zone into the above-ground zone without leaving a cold band. At the same time, the plinth requires protection against splash water and damage. The finishing layer must belong to the appropriate solution. It is not assumed that a façade render applied below ground will act as waterproofing.
At basement windows, the reveals, window sills and connections to light wells matter. Water should not run into unsealed joints. The thermal insulation must be brought close to the frame according to the detail, without covering required openings and making operation difficult. Before bonding the boards, it is worth checking whether, after increasing the insulation thickness, there will still be room for all the flashings.
How should the masonry and the water protection be prepared?
On an old wall, leaks, salt contamination and the condition of the joints are identified first. The bituminous layer must have a suitable substrate and continuous connections. Bonding EPS will not repair cracked waterproofing. If the wall is damp, the source of the water and the drying conditions must be established. Sealing the problem under a new covering may make later repair more difficult.
The adhesive should be compatible with the coating and not damage the polystyrene. The work is carried out under the conditions specified in the material instructions. Before backfilling, the connections are inspected and photographic documentation is made. The backfill and its compaction must not damage the layers, particularly at corners, pipe penetrations and insulation terminations.
What should be checked after use begins?
In a heated basement, air exchange appropriate to the function of the rooms must be ensured. A warm wall does not remove the vapour produced when drying laundry, bathing or cooking. It is worth monitoring temperature and humidity and observing the corners. The new finish should be applied once the conditions required by its manufacturer have been achieved.
If stains appear despite the thermal insulation, their location helps with diagnosis but is not conclusive evidence. The cause may be a leak, rising damp, a thermal bridge or excessively high air humidity. The repair is selected once the mechanism has been established. Adding further centimetres of EPS without identifying the cause does not give a reliable result.
Variants of EPS for various applications are offered by, among others, Ekobud, Sonarol, Austrotherm and Polstyr. In a basement, the documentation for the selected board and for the entire system is what matters.