IKO enertherm ALU: class F and B-s2,d0 in the end-use application
At a glance
Both F and B-s2,d0 appear in the IKO enertherm ALU documents. This does not mean two interchangeable classes from the same assessment. The first designation refers to the product, the second to the specified end-use application. Before entering the class in a project, it is necessary to establish what the cited document actually describes and whether its conditions correspond to the planned building element. IKO enertherm ALU is a PIR board with a multi-layer aluminium facing on both sides. The manufacturer declares reaction to fire class F for the product itself. It also declares B-s2,d0 for a specific end-use application on a steel substrate. What is decisive, therefore, is not the symbol itself but the object and the conditions of the assessment.

First establish the subject of the classification
A summary that removes the reference to the method of installation loses part of its meaning. The result obtained for the specified assembly must not automatically be attributed to every wall, floor or roof using this material.
A practical check begins with the full name on the label. Next, the document for that variant must be found, and product data must be distinguished from the description of the application. PIR boards of one family may have different facings, edges and intended uses. A short entry in the bill of quantities is therefore not sufficient for a fire assessment. A cross-section showing the actual substrate, protective layers and the way the joints are made is also needed.
Example of an error when transcribing data
Let us imagine a bill of materials in which B-s2,d0 is entered next to the name ALU without any additional note. The board is then installed in a different type of building enclosure than the one described in the manufacturer’s documentation. Such an entry does not yet confirm that the requirements of the new solution are met. Verification consists in comparing the scope of the document with the design, not in choosing the more favourable symbol. If the conditions differ, the designer must establish what confirmation is needed for the actual application.
No average is calculated between F and B-s2,d0. Nor can it be assumed that a thicker layer automatically achieves a better class. The symbols describe the result of a specific classification. A change in thickness, method of fixing or adjacent layers should be checked within the limits of the relevant document. The name polyurethane foam alone gives no basis for transferring a class from one product or assembly to another.
Reaction to fire does not specify a fire resistance duration
Reaction to fire describes the behaviour of the product within the scope of a given classification. Fire resistance concerns the ability of a building element to perform specified functions for a required period. These are separate assessments. No number of minutes of resistance of the complete building enclosure is derived from the letter F or the designation B-s2,d0. Likewise, the aluminium top surface of the board is not on its own proof that the entire assembly is non-combustible. The required document must be matched to the question it is meant to resolve.
When a requirement for the entire roof appears in the design, the check does not end with the PIR data sheet. It is necessary to determine which element and which property the requirement relates to. The complete solution is then checked together with its limitations. In the documentation, full names of the assessments should be used so that the contractor does not treat the result for one material as an approval for all layers. This order also helps when assessing proposed substitutions.
Thermal and mechanical data remain a separate matter
For IKO enertherm ALU the declared lambda is 0.022 W/(m·K). The manufacturer also states a compressive stress of at least 175 kPa at 10% deformation and more than 95% closed cells. None of this information replaces the fire classification. The favourable thermal resistance allows the insulation thickness to be considered, but it does not explain how the complete cross-section behaves during a fire. The compressive stress figure is also neither a fire class nor a ready-made permissible roof load.
In the comparison table, it is therefore worth keeping separate fields for name and thickness, thermal properties, mechanical requirements and the relevant fire documents. Polyurethane boards should not be compared by means of a single selected figure. Data organised in this way make it possible to notice an offer that retains the lambda but changes the condition of use. A change in price then becomes visible together with the change in the scope for which the given product is responsible.
How to check a proposed substitution during construction
If the supplier proposes a different ALU variant, its full designation must be obtained before installation. The documents must then be compared with the requirements specified for the particular cross-section. A similar laminate colour or an identical thickness does not confirm equivalence. What matters is the actual variant, its facing and the scope of the assessed use. Polyurethane insulation should be considered together with the materials with which it forms the adopted solution.
It is worth retaining the designer’s decision record and the delivery marking. If a discrepancy arises, it should not be covered up with a general note about material conformity. The specific item in the documentation and the way the doubt was resolved must be indicated. Site photographs can show the sequence of layers and the joints made. However, they do not replace the classification, nor do they allow the class to be determined independently from the appearance of the board.
A valid conclusion has a defined scope
A well-prepared description explains when it refers to the IKO enertherm ALU board itself and when to its specified end use. It keeps F in the appropriate place and the conditions accompanying B-s2,d0. It does not add the resistance duration of the building component on the basis of these symbols. The assessment concludes with the linking of the documents to the actual cross-section. Polyurethane insulation here means a deliberate choice of product for a solution whose requirements have been defined separately for each relevant function.