Deformation of the roof where equipment is placed over BauderPIR FA requires an assessment of the actual support conditions and the duration of the load. The foot may touch the covering with only part of its base, which changes the pressure transmitted to the layers beneath it. The stiffness of the board and the result of the compression test do not on their own describe such a detail. First, the force, the actual contact area and the condition of the covering and protective layers must be established; these must then be related to the design of the support. The guide separates the short-term material test from the long-term performance of the insulation and identifies the data needed to diagnose local damage and choose the scope of repair.

Dark face over a pale core with a profiled edge, illustrating BauderPIR FA

First, the question of the cause

Document the actual condition: a drawing of the support with the load transfer path and a description of the protection of the covering. Compare the execution with the solution that was intended to combine insulation performance with permissible deformation under load. Without this reference, it is easy to attribute a property of the board to a defect in the bond between the layers.

The actual product and the scope of its data

The BauderPIR FA product data sheet states λD 0.022 W/(m·K), CS(10/Y)120 and fire reaction class E. The Polish data sheet of September 2026 also contains a separate value of 24 kPa for long-term load at 2% deformation, different from the test result at 10%. When assessing a roof with equipment based on the layers above the insulation, it is therefore necessary to separate the properties of the board itself from the behaviour of the entire assembly: the design of the support must take into account the conditions of the documentation and all layers of the system, and CS is not a load-bearing calculation for the finished roof. In the order, the full name BauderPIR FA replaces the generic term polyurethane boards; the PIR core and the facings together form the properties of the complete board.

How to read a simple example

For example, let us take only a force of 1.00 kN and an actual contact area of 0.015 m²; the quotient gives an average pressure of 66.7 kPa. With BauderPIR FA it is not enough to relate this figure to the 120 from the CS parameter, since the Polish data sheet states 24 kPa separately for long-term load and 2% deformation. It is therefore necessary to trace the distribution of the force and the conditions of the entire detail, bearing in mind that this is neither a design nor an approval of the support. The prerequisite remains the transfer of forces from the equipment to the structure in accordance with the design, and the nominal outline of the base plate does not have to mean contact over the entire surface.

A photograph of the upper part of the base may not show the actual contact with the roof. Local unevenness or areas without contact may remain under the foot. The inspection should establish what part of the surface actually transmits the force. Only this information can be compared with the calculation assumption. Assigning the entire outline as the contact area beforehand could underestimate the result.

The BauderPIR FA example links the result to the actual size of the load-transferring surface. A separate assessment of short-term compression and permanent load does not explain the cause of every defect. At this point, check in turn the force, the bearing area and the deformation over time before drawing a conclusion. Compare with the document containing the pressure calculation and the conditions of its long-term action; if the data deviate from the actual situation, first correct the description of the board and the layers.

Matching the action to the identified problem

Increasing the force-distribution area and separate support are two different solutions. The choice lies with the designer of the support and the roof loads, who knows the load path. The value of 120 kPa is not the permissible load of the finished support. For BauderPIR FA, documents on penetrations and the service route are also needed so that the repair covers the entire loaded section.

What can be seen at the joint

The inspection of BauderPIR FA covers the area around the base of the unit, where the insulation must connect, and the condition of the aluminium facing under the protective layers. A different shade of the print does not indicate damage; an open gap, a loss of facing or permanent deformation is a separate category of symptom. The reference is the document with the pressure calculation and the conditions of its long-term action. On the other side there is, or is to be, a covering with a protective layer under the support, which affects access to the damaged location. In the note, record whether the contact area of the unit’s foot was inspected directly or inferred from the adjacent surface.

How to separate a feature from a defect

The support design must explain the load path from the unit to the structure, taking into account the actual contact area and the protection of the covering. BauderPIR FA is one of the elements of this section. If the damage affects several layers, the designer should compare the support drawing with the opening-up before determining the method of reinstatement.

A conclusion should have limits

For the BauderPIR FA documentation, add the calculation of the compressive load and the conditions of its long-term action, together with a description of the area actually exposed under the foot of the equipment. Record separately the further openings required, the service penetrations and the maintenance route. The purchase of repair boards should take place after checking the load-bearing capacity of the layers, the contact area and the deformation over time.

7 branches. Materials closer to your project.

Izoprofil.org map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E
  • BŁONIE — ul. Sochaczewska 138A
  • RADOM — ul. Grobickiego 8
  • ŁÓDŹ — Natolin 8
  • OLSZTYN — Barczewo, ul. Prosta 9
  • WROCŁAW — ul. Jerzmanowska 10C
  • GORZÓW WLKP. — ul. Zielona 33/34

Check prices and availability: +48 500 409 109

Free quote