PIR insulation
BauderPIR FA: why coverage dimensions are smaller than board dimensions
At a glance
A shortfall of BauderPIR FA boards when laying the last row may result from confusing the board outline with the coverage dimension. The large-format element has a milled edge, so part of the width disappears into the lap rather than representing missing material. Before concluding that the delivery is incomplete, the roof measurement must be compared with a cutting plan based on the effective coverage dimension, and the condition of the delivery and the method of cutting must then be checked. Only this sequence allows a calculation error to be distinguished from actual losses at the perimeter and at penetrations.

First, the question of the cause
The condition of the layers and the junction detail must be related to the cutting plan drawing in order to assess whether the overlaps and cut-offs fell within the intended solution. Without this reference, it is easy to attribute to the board a characteristic that results from fitting to the edge. The assessment concerns the conformity of the detail, not the product itself.
The actual product and the scope of its data
In BauderPIR FA, the PIR core is enclosed by aluminium facings on both sides, and the 15 mm wide rebate defines the lap between boards. The outline of 2400 × 1200 mm differs from the installation dimension of 2385 × 1185 mm, which is why the full name BauderPIR FA is needed when checking an order, and generic “polyurethane boards” are not sufficient. The declared λD is 0.022 W/(m·K), the compressive stress level CS(10/Y)120, the reaction to fire E. The large format does not make the board a self-supporting structural element; the assessment concerns the thermal insulation of a large, regular roof area.
How to read a simple example
One FA board has an outline area of 2.8800 m². The coverage dimension of 2385 × 1185 mm, however, gives 2.826225 m². The difference is approximately 0.054 m² per board, before any cutting is taken into account. For an example of 20 full boards, we obtain approximately 56.52 m² of coverage instead of 57.60 m² of outline. This is not a shortage of material in the delivery. Part of the area corresponds to the geometry of the laps. Waste, damaged pieces and cut-offs at the perimeter must be calculated separately. A calculation separated in this way makes it possible to check where the shortfall visible at the last row comes from.
In BauderPIR FA, the coverage dimension of 2385 × 1185 mm is an installation dimension, not the outline. The 15 mm rebate and the FA designation make it possible to confirm the element on site. Before concluding that there is a shortage, compare the external dimension with the installation dimension and check the product description and the condition of the layers.
Matching the action to the identified problem
Regular rows of full boards are laid differently from a fitted layout in zones with numerous cuts. In BauderPIR FA, the board field and the rebated edge of the 2400 × 1200 mm sheet are considered separately, because the rebate determines the actual coverage. Ordering by the outline alone without taking the rebate into account overstates the coverage of a single board and may understate the number of boards needed. The pallet layout plan is linked to repair or reordering through the survey and roof-area coordination lead who knows the requirements of the whole cross-section.
What can be seen at the joint
The inspection of BauderPIR FA is intended to confirm the condition of the rebate forming a 15 mm lap and to assess the state of the aluminium facing on both sides. A different print colour does not prove an open joint, loss of facing or permanent deformation; the reference is the FA marking and the 15 mm rebate. A covering matched to the BauderPIR FA layout on the other side may hinder access to the damage. The note distinguishes whether the inspection covered the rebated edge of the large-format board or whether only the adjacent board field was accessible.
How to distinguish a feature from a defect
Large BauderPIR FA sheets need the support provided for in the roof build-up. The row plan determined from the effective coverage should also show cut pieces and laps. Comparing this plan with the exposed area allows the survey coordinator to separate a material shortfall from a support problem.
The conclusion should have limits
Before reordering BauderPIR FA, check the FA marking, the 15 mm lap and both dimensions: the overall size and the coverage. From the number of boards per pallet, calculate the usable area, taking account of cutting losses. The pallet and work-area layout plan should refer precisely to this area.