SOPREMA EFIGREEN ITE: the function of the facing and board joint

At a glance

A symptom at the window in a wall insulated with the ITE system requires establishing whether it concerns the board itself or the entire assembly with the façade facing. In the case of EFIGREEN ITE, the inspection must be based on the external window reveal and the adjacent façade bracket, because that is where the layers intersect. The mere presence of a tongue and groove does not eliminate thermal bridges from elements penetrating the insulation. The diagnosis should therefore indicate which part of the joint was actually examined, what width the reveal has and how the fixings were routed through the thermal insulation layer. Without this, it is impossible to separate the properties of the board from the behaviour of the entire assembly.

Greenish board standing upright, accompanying the EFIGREEN ITE discussion

First, the question about the cause

A reveal section showing the junction between the board and the supporting substructure is the reference measure for the inspection. Compare the condition against it: whether the insulation fitted without clashing with the window finish and whether the layer remained continuous. Against this background you can distinguish a characteristic of EFIGREEN ITE from a defect in the detail.

The right product and the scope of its data

In the question about the facing and the tongue-and-groove joint of EFIGREEN ITE, it must first be established what the stated data refer to: the PIR board itself or the entire building element. For this product the manufacturer specifies λ 0.023 W/(m·K), CS(10/Y)150 and fire reaction D-s2,d0; these are not transferable to any roof board of this brand. The available formats are 2500 × 1200 mm or 1200 × 1000 mm, and the application requires a compatible fixing and façade finish solution. When checking an order, the name EFIGREEN ITE is needed, because generic “polyurethane boards” do not identify this product. The core is PIR foam, while the aluminium facings and the tongue-and-groove joint belong to the complete board, so their function cannot be assessed on the basis of the core alone.

How to read a simple example

Let us consider two actual thicknesses of EFIGREEN ITE: 80 and 100 mm, at a lambda of 0.023 W/(m·K) applicable to the variants under consideration. The simplified thermal resistances are approximately 3.48 and 4.35 m²K/W respectively. Such a difference may explain part of the discrepancy if the material thickness was incorrectly identified. It does not, however, prove that a specific symptom has precisely this cause. The record confirming the ITE variant and the conformity of the fixing with the design must be verified. The external window reveal and the adjacent façade bracket require separate assessment. The calculation helps to test the hypothesis only once the data have been correctly gathered.

For a window frame, the choice of EFIGREEN ITE is determined by the space available beneath the facing and by how the junction with the window runs. Lambda 0.023 W/(m·K) and the tongue-and-groove joint do not describe the path by which rainwater is drained away. Trace it on the detail and compare the designation of the ITE variant and the fixing with the design.

Matching the action to the identified problem

The board thickness in the middle of the wall field does not determine how the joint at the window behaves. In EFIGREEN ITE, the reveal and the façade bracket must be assessed separately, because the junction with the opening has a different layer build-up from the middle of the building element. The tongue-and-groove joint connects the boards, but it does not fix the facing or transfer façade loads. Where doubts cover several layers, the scope is determined by the designer of the façade and of its junctions with openings, on the basis of a section showing the thermal insulation, supporting substructure and facing.

What can be seen at the joint

Check the factory tongue-and-groove joint, the sealing tape at the joint and both aluminium facings. An open gap, a loss of facing and permanent deformation are damage, not a difference in printing or colour. Compare the condition with the record confirming the ITE variant and fixing in accordance with the design. Note whether the external window reveal and the adjacent façade bracket were inspected directly or inferred from the adjacent surface, and whether the finish in the confirmed system hindered access to the damage.

How to separate a feature from a defect

Forces from the façade supporting substructure must reach the load-bearing wall through the designed fixings. In the case of EFIGREEN ITE, check their routing within the confined space of the reveal. A section covering the board, the bracket and the window finish gives the designer a basis for agreeing the repair of the entire junction.

The conclusion should have limits

When preparing an order for the reveal, describe EFIGREEN ITE, the supporting substructure and the façade facing together. Indicate whether the condition of the bracket and of the junction with the window was confirmed directly or whether a wider opening-up is needed. The reinstated rainwater drainage path and the routing of the insulation will indicate the scope of work without conflicting with the window finish.

7 branches. Materials closer to your project.

Izoprofil.org map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E
  • BŁONIE — ul. Sochaczewska 138A
  • RADOM — ul. Grobickiego 8
  • ŁÓDŹ — Natolin 8
  • OLSZTYN — Barczewo, ul. Prosta 9
  • WROCŁAW — ul. Jerzmanowska 10C
  • GORZÓW WLKP. — ul. Zielona 33/34

Check prices and availability: +48 500 409 109

Free quote

Materials for your project