After a basement flood, EPS cannot be assessed solely on the basis of a dry surface. It is necessary to check how far the water penetrated, whether it was contaminated and what the condition of the entire building component is. Sometimes it is possible to dry out the assembly, and sometimes the layers must be replaced. First comes the safety of the building and its installations, then the repair plan and monitoring of the drying process. After a flood or serious inundation, the condition of the structure and installations must be assessed before renovation begins. A high external water level can be relevant to how water is removed from the basement. Rapid emptying of the rooms should not begin without first establishing the conditions. Work on damaged installations requires appropriate specialists.

White EPS board on a grey surface next to gloves and a meter

First, safe access to the rooms

It is worth documenting the flooding level and visible damage. Photographs, dates and a description of the source of the water will help when determining the scope of the repair. A failure of a clean water installation and an inflow of sewage are different situations. Contaminants can get under the floor finish and between the boards, even though after the water has been pumped out the surface of the room already looks relatively good.

Where can water remain?

In a floor, water can get under the screed, between the EPS layers and at the horizontal waterproofing. In wall insulation it can remain behind the boards or in cavities. A dried-out surface does not prove that all concealed places are dry. The scope of the investigation should correspond to the route by which the water entered the building element and to the duration of the flooding.

A board with limited water absorption does not guarantee that the entire assembly is dry. The WL(T) parameter relates to a laboratory test of the material, not to joints and connections on site. Even thermal insulation that has retained its shape can make access to a contaminated substrate difficult. The decision therefore concerns the entire building element, not merely the question of whether the polystyrene has disintegrated under the influence of water.

When is keeping EPS considered?

Whether the insulation can be left in place is assessed on a case-by-case basis. The absence of damage, the adhesion, the degree of moisture and the possibility of effective cleaning and drying all matter. In a wall it must be checked whether the flow or pressure of water has detached the boards. In a floor, the condition of the substrate, its deformation and the stability of its support are also important.

One should not promise to save every EPS layer merely because the material usually absorbs little water. Equally unjustified would be automatically stripping out every assembly after a minor incident. The decision is based on visual inspection, measurements and the possibility of reaching the damp places. In the event of contamination, an assessment of the sanitary conditions is also required.

When might replacement be necessary?

Boards that are deformed, mechanically damaged or debonded should not be covered with a new finish without repair. Replacement may also be needed when the layers cannot be effectively cleaned after contaminated water. The absence of visible mould does not determine whether contamination remains in a covered assembly. Odour is also not a complete test of the condition of the materials.

Demolition must be planned so as not to damage the elements that are to remain. Waste after flooding may require different handling from clean offcuts from a new build. It should not be mixed without identification with material intended for reuse. The scope of dismantling should make it possible to repair the substrate, not merely to expose one easily accessible section.

How should drying and monitoring be carried out?

Drying is selected according to the layer build-up and the source of the water. There is no universal time after which every floor is ready to be closed. Measurements at the appropriate locations and observation of their changes are important. Heating the room alone may not remove water from a tightly covered space. The method should be selected after identifying the construction of the building element.

No random holes are made in the waterproofing, and the EPS is not heated to a high temperature. Every intervention should have a defined purpose and a subsequent method of restoring the layers. In the case of contamination, proper cleaning is needed before covering. Renovating the finish too early may hinder further drying and again enclose the problem inside the floor or wall.

What should be changed when rebuilding the building component?

The repair should remove the path by which water enters. The installation, the waterproofing joints, the drainage and the areas around thresholds must be checked. New boards are selected to suit the place of work and the required loads. Changing to a higher EPS class will not repair a leaking detail. Likewise, a better lambda value is not a safeguard against another flooding.

Before closing the layers, it is worth keeping the assessment record, the measurement results and photographs. It is good to describe the material used and the way the joints were recreated. The documentation will make later inspection easier and help avoid repeating the same defect. The ultimate aim is a dry, stable and properly protected building element, not merely restoring the basement’s original appearance.

New EPS boards for various applications are offered by, among others, Austrotherm, Polstyr, Dom-Styr and Ekobud. The material manufacturer does not replace the assessment of the condition of the flooded building.

7 branches. Materials closer to your project.

Izoprofil.org map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E
  • BŁONIE — ul. Sochaczewska 138A
  • RADOM — ul. Grobickiego 8
  • ŁÓDŹ — Natolin 8
  • OLSZTYN — Barczewo, ul. Prosta 9
  • WROCŁAW — ul. Jerzmanowska 10C
  • GORZÓW WLKP. — ul. Zielona 33/34

Check prices and availability: +48 500 409 109

Free quote