PIR and phenolic foam: making sense of Kingspan board names

At a glance

Kingspan Therma TR26 and Therma TR27 have a PIR core, whereas the Kooltherm family uses phenolic foam. The manufacturer’s name therefore does not by itself identify the insulation material. Products that look similar may differ in core, facing and function within the building element. If the project description gives only the Kingspan brand, it must be supplemented with the family, the variant and the intended place of application. Only such a designation allows the correct parameters to be read and the proposed substitution to be assessed. Neither a small thickness nor the colour of the surface is proof of equivalence. The thermal insulation board must also be distinguished from a complete panel with structural facings: in these products, other components are responsible for transferring loads and making the joints.

Section of a PIR board with silver laminate texture on an orange background

First, identify the function

The manufacturer’s name covers various materials, including PIR Therma and phenolic Kooltherm, so omitting this distinction leads to an error in the assessment. Correctly selected PIR boards should clearly indicate the material suited to the designed function and method of installation. During the inspection, compare the full product name, the core type, the property document and the place of application in the building with the documentation or with the condition before the change.

How to interpret the values

Identical thickness of TR26 and TR27 does not guarantee the same thermal effect. For Therma TR26, 0.022 W/(m·K) is stated, whereas in Therma TR27 the declared lambda value varies with thickness. First, the variant of each board must be identified, then the corresponding insulation result calculated and compared.

The Kingspan variants being compared should be set side by side at the same required thermal resistance, because the number in the offer alone does not explain the conditions of its use. Attributing a lower lambda to the whole brand distorts the parameters of the other product families, which is why thermal equivalence is checked at the level of precisely designated offer variants. Before assessing the savings promise, ask for the lambda for the selected thickness, the appropriate RD and the consequences of changing the build-up height.

PIR, phenolic foam and structural insulated panel are three different products, not three names for one product. In the Kingspan range there are boards with different cores and functions: Therma TR26 or TR27 is a specific insulation board, and Kooltherm does not become PIR just because it has a similarly small thickness. Recognising the name and construction of the product is a precondition for a meaningful comparison of parameters and for assessing any substitution of material.

A symptom does not always indicate the cause

The Therma insulation board is a different product from a complete sandwich panel with structural facings. The load-bearing function, the fixing and the execution of the sealing layers must be attributed to the actual solution, not to the insulation alone. If there is a suspicion of a water or moisture problem, check whether the insulation product has not been changed in a build-up with separate vapour control and water protection layers.

A material substitution must preserve the continuity of the designed water and vapour protection before the cause of the problem is attributed to the product name or facing. The phrase “polyurethane foam” alone explains nothing, because a similar board colour does not prove the same conditions of connection to the membrane or flashing. Compare the description of all layers, the perimeter details and the scope of documentation of the proposed replacement with the history of the problem’s occurrence before you identify the cause.

Where to look for discontinuities

TR26 has a facing containing aluminium, and TR27 has a glass fibre facing. These surfaces differ in construction, so they must match the way the layers of the designed roof are connected. When looking for the cause of a local discontinuity, check whether the aluminium facing of TR26 has not been replaced in the roof description by the glass fibre surface of TR27.

When replacing the board, check that the new facing is compatible with the fixing and the covering, even if the finished surface looks even and neatly finished. A common PIR core does not authorise replacing the product without assessing the connections between the layers, so analyse the method of connection. Identifying the cause must preserve the function of every joint after the material substitution proposed during construction. To assess the performance of the polyurethane insulation at this location, gather the type of surface, the permitted method of connection and the geometry of the sides in both compared boards.

Assessment of the material’s condition

The reaction to fire of the material and the fire resistance of the building element are different properties, and the compression result at 10% deformation is not a ready design load value. When reading the product data sheet, separate the data on the material’s reaction to fire, compression and the fire resistance of the entire building element.

Assign each Kingspan parameter to the correct test and scope of application, so that a test result does not become permission for arbitrary use. One favourable property of a board does not prove compliance with every requirement for a building. In case of discrepancies, ask for the full declaration for the variant and for documentation of the assembly with regard to load-bearing capacity and fire requirements, rather than a repetition of a general assurance about the quality of the board.

Matching the solution to the problem

The wording “Kingspan polyurethane insulation” requires clarification: which product and which thickness are specified? A similar surface colour or a similar name of another board does not confirm interchangeability. Likewise, the shared PIR designation does not settle the assessment; a proposal to substitute the material must be analysed in terms of its effect on the other parts of the assembly.

The price difference between Kingspan boards can only be assessed once it is set against changes in the adjacent layers – a different scope of application may explain the cost better than a saving with the same effect. Therefore, before approving the purchase and changing the construction documentation, the criteria for equivalence must be agreed: the required thermal resistance, the geometry, the method of fixing and the cost of adapting the adjacent layers.

7 branches. Materials closer to your project.

Izoprofil.org map of seven branches offering sandwich panels, PIR boards and sheet metal