At a glance

Fire safety for a roof with Eurothane Silver requires checking the classification that applies to its actual build-up. Eurothane Silver is a PIR board with multi-layer gas-tight foil on both sides and a printed grid, intended in the current datasheet for flat roofs in a classic build-up. The fire class assigned to the board alone and the class for a specific end use come from separate assessments, so they cannot be compared without checking what each entry refers to. This distinction helps avoid both unjustified concerns and presenting PIR as a non-combustible material.

Board section with a regular grid on its facing, accompanying the Eurothane Silver article

The product’s construction explains its application

Before ordering the insulation and the waterproofing membrane, one agreed assembly must be established, because the board’s broad range of applications does not authorise combining components from different systems. During the inspection, the substrate, the waterproofing variant and the way the roof layers are joined are compared with the documentation or with the condition before the change.

How to read thermal parameters

When assessing an existing roof with Eurothane Silver, the declared lambda of 0.022 W/(m·K) for the 20–200 mm range alone does not determine the cause of the thermal problem. A distinction must be made between the property of the board and the performance of the entire assembly: compare the thickness resulting from the calculations with the actual condition, and relate the result to the continuity of the layers and the manner of installation.

The Eurothane Silver layer is selected according to the lambda of 0.022 W/(m·K) and the required roof height, but this figure alone does not describe the conditions of use. The influence of the fasteners and terminations is verified in the calculation of the entire roof, because the R of an equivalent section of the board does not include a correction for each fastener penetrating the insulation. To assess the promised savings, the thickness of the main field, the number and type of fasteners and the detailing of the thermal insulation perimeter are required.

An NPD for reaction to fire for the 20 mm Eurothane Silver variant is not a class equivalent to E or F. It means that no declared result exists for this characteristic. B-s2,d0, by contrast, relates to a specific end use. A comparison of these statements without indicating the scope may appear contradictory, even though they describe different situations. Correct interpretation requires checking the thickness, the characteristic and the assessment conditions at the same time.

Moisture must be identified, not merely covered up

Moisture in a system with Eurothane Silver must be identified before the gas-tight surface of the board is regarded as the closure of the entire roof. The vapour control layer and the waterproofing are selected according to the building’s conditions, and when assessing an existing assembly it is checked whether the joints between the elements remain open.

At the junction of the roof with the parapet and at service penetrations, check the waterproofing and the continuity of the vapour control layer separately. The gas-tight Eurothane Silver foil covers the surface of the board, not all the joints between components. Compare the upstand of the covering and the sealing of the penetration with the history of moisture, in order to identify any defect in the detail.

Where problems at the junction arise

The 600 × 1200 and 2400 × 1200 mm formats and the restriction of the 20 mm variant to the smaller format help to identify the scope of the repair: in the case of an existing roof, the dimension of the supplied board is compared with the actual layout of the roof slope and the availability of the variant for the adopted thickness.

A discontinuity in the insulation may already result from the ordered board format — 600 × 1200 or 2400 × 1200 mm — and the type of edge. The 20 mm thickness appears in the data sheet only in the smaller format, so the layout of the boards on the roof slope must be matched to the thickness supplied. Compare the dimension of the supplied board, the edge (straight or rebated) and the coverage area with the number of obstacles on the roof; the appearance of the laid surface alone will not explain this.

The limits of conclusions from the product data sheet

In the September 2026 Eurothane Silver data sheet you will find CS120 for 20 mm and CS150 from 30 mm. The reaction to fire of the board itself from 30 mm is designated class F, whereas for 20 mm it remains undetermined. These two entries relate to different thicknesses and different characteristics, so when determining the causes of discrepancies in the assessment of the roof, it is first necessary to check which thickness and which declaration the reading refers to.

When changing the board thickness, the mechanical parameters and the scope of the fire declaration must be read again: the data sheet specifies CS120 for 20 mm and CS150 from 30 mm. The B-s2,d0 classification applies to the stated use on sheet metal, not to a board laid in any arbitrary way. Check the correct row of the parameters table and the classification conditions that correspond to the planned construction, instead of relying on a general assurance of quality.

Practical inspection of the completed assembly

When identifying the causes of defects in an existing roof, record in the Eurothane Silver offer the thickness, the edge and the covering system, because visually similar PIR boards may have a different scope of application or different mechanical properties. Only such a description allows the properties of the board itself to be separated from the behaviour of the entire assembly and makes it possible to assess whether the stated cause results from the product selection or from the layer build-up.

When comparing silver boards of similar appearance, first establish whether they belong to the same roof system. In assessing a Silver substitute, the facing and the manner of application matter, not the thermal parameters alone. The printed grid does not determine suitability for the intended covering, so without a description of the scope, the cost per square metre of insulation cannot be reliably compared. Before concluding on cost-effectiveness, check the full name Eurothane Silver, the thickness, the side profile and the scope of work involved in closing the roof.

7 branches. Materials closer to your project.

Izoprofil.org map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E
  • BŁONIE — ul. Sochaczewska 138A
  • RADOM — ul. Grobickiego 8
  • ŁÓDŹ — Natolin 8
  • OLSZTYN — Barczewo, ul. Prosta 9
  • WROCŁAW — ul. Jerzmanowska 10C
  • GORZÓW WLKP. — ul. Zielona 33/34

Check prices and availability: +48 500 409 109

Free quote